Versamax molecular devices. Product Overview VersaMax™ ELISA Microplate Reader Manufacturer Molecular Devices® | Available Worldwide Be the first to review this product Request Pricing Molecular Devices® Manufacturer Website. Versamax molecular devices

 
Product Overview VersaMax™ ELISA Microplate Reader Manufacturer Molecular Devices® | Available Worldwide Be the first to review this product Request Pricing Molecular Devices® Manufacturer WebsiteVersamax molecular devices  The cytokine concentration was calculated from the standard curve using seven-parameter curve fitting software (SOFTmaxPro 5

The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility offered by monochromator-based systems. The concentrations of anti-RSV G protein IgG antibodies in the samples were. The samples were incubated with FBS, and the optical density of particles was determined with a microplate reader (VERSAmax, Molecular Devices, Sunnyvale, CA) by measuring the absorbance at 560 nm for 2 h. Brand: Molecular Devices | Category: Laboratory Equipment | Size: 0. This manual does not represent a commitment on the part of Molecular Devices Corporation. We use. ces at one of the following telephone numbers: 408 747-1700 800 635-5577 U. Sale. 9000-0756. Get pricing and purchase lab equipment and. Shark chondroitin sulfate A sodium salt (Sigma Aldrich Corp. The mixture was incubate at 37 °C for 30 min, and then the reaction was stopped by the addition of 0. The reaction was started by adding 10 µL of the enzyme solution (properly diluted) to 190 µL of 15 mM ONPG in 0. Cell viability was represented by percentage values compared to a. pneumoniae ATCC49619 was used as reference control strain as recommended (Clinical and Laboratory Standards Institute. JEG-3 cells were transfected with myc-tagged NDRG1 wild type or deletion mutants at the N- or C- terminal as depicted in Figure 5A. 滤光片型光吸收微孔板读板机(酶标仪),简单易用,性价比高,检测结果精确. Lihat Video. By measuring optical pathlength, it eliminates the last major distinction between microplate readers and spectrophotometers. Whether bacteria were partially or completely inactivated by bone cement. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. New and used Molecular Devices VersaMax's for sale on LabX. Microplate Readers Thermo Fluoroskan Ascent FL Fluorescence Microplate Reader. New and used Molecular Devices VersaMax's for sale on LabX. 9. Table of Contents. The blue formazan concentration formed in viable cells was measured at 570 nm using spectrophotometer (Versamax, Molecular Devices, São Paulo, Brazil). The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. The signal produced was proportional to the amount of analyte present and interpolated from the calibration curve presented on each plate. 00 USD. Add to Cart. 5577; General Inquiry Form; Mon-Fri 8:00am - 5:00pmSpectraMax and VersaMax . Cyanobacterial strains that did not lyse until the 12th day were defined as insusceptible. To provide access to disconnect power from the instrument, maintain a 20 cm to 30 cm (7. 파장 정확도 : < ±0. With optimized reagents, option to operate the. 0. VCAM and ICAM were quantified by ELISA using a spectrophotometer (VERSAmax Molecular Devices) following the manufacturer’s protocol (DY643 and DY796, R&D Systems, Minneapolis, MN, USA). ® SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Concluding Remarks. A. Statistical analysisThe absorbance was measured using a microplate reader (VERSAmax; Molecular Devices, San Jose, CA, USA) at an excitation wavelength of 530–560 nm. # SMP54-GXP- 10UL) Pyrochrome Assay. Molecular Devices also offers a mass spectrometry-based solution for food safety testingWe would like to show you a description here but the site won’t allow us. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. One microgram of RNA was. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. #VERSAMAX) SoftMax Pro GxP Software version 5. Tristar 3 Multimode Microplate Reader. measured over 60min using a microplate reader (VersaMax, Molecular Devices, Sunnyvale, CA) at a wavelength of 405nm. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. The optical densities (ODs) of the reactants were measured at 450 nm using a microplate spectrophotometer (Versamax, Molecular Devices, CA, USA). , VersaMax; Molecular Devices) Incubator for cell culture. 2 and 648. SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. This version is compatible with the following instruments: SpectraMax® Mini Multi-Mode Microplate Reader (software version 7. Molecular Devices公司的VersaMax读 板机为光栅型单色器读板机,拥有灵活检 测优势,无需加配额外的滤光片。 可调波长,无需滤光片,灵活 VersaMax读板机使用光栅单色器来选择 波长,其结果是选择确切的检测波长应用 于每个实验。波长范围从340nm到 With the VersaMax microplate reader, you will never have to buy another filter. The samples were incubated with FBS, and the optical density of particles was determined with a microplate reader (VERSAmax, Molecular Devices, Sunnyvale, CA) by measuring the absorbance at 560 nm for 2 h. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. Used. Absolute values were attained with a standard curve composed of type I bovine skin collagen solution (0. The Molecular Devices SpectraMax 384 Plus is a UV/Vis spectrophotometer and microplate reader combination for more reliable and fast data reporting with built-in cuvette port and microplate drawer. Proliferation was assessed by bromodeoxyuridine (BrdU) incorporation (Cell Signaling Technologies). Ensure data accuracy of your reader. The preparation of cytoplasmic and nuclear proteins was performed by using NE-PER Nuclear and Cytoplasmic Extraction Reagents (Invitrogen, USA) according to. Tristar 3 Multimode Microplate Reader. SpectraMax®, VersaMax, VMax. Table 1 Conditions for biofilm formation on lids of 96-pin microtiter plates. Our products enable scientists to improve productivity and efficiency in scientific discovery and research. Used. p-nitrophenol (Sigma) with diluted concentrations ranging from 0 to 0. 1. Total. As a result, assay flexibility is consequence-free. 0200-6117. Cell-free AB broth (22) of an overnight culture of the acylhomoserine lactone-defective V. Proliferation of the released daughter cells was monitored at a wavelength of 578 nm online by a microplate reader (VersaMax; Molecular Devices, Sunnyvale, Calif. MDC instruments including: SpectraMax®, VersaMax. To make your request, nothing more simple: you just have to connect on the site and to make your request on line. The amount of MTT reduction was measured immediately by detecting absorbance in a microplate reader (Versamax, Molecular Devices) at a wavelength of 570 nm and a reference wavelength. They were then pre-treated with indicated concentration of drugs for 1 h prior to being treated or not with 5-HT or serum. Enzyme activity was. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. Wavelength Bandwidth °¤ 2. It covers everything from installation, configuration, data acquisition, data analysis, curve fitting, to reporting and troubleshooting. 2. The SpectraTest® ABS1 Absorbance Validation. $1,195. The cellular viability. 2 GxP Software is the latest, most secure software to achieve full FDA 21 CFR Part 11 and EudraLex Annex 11 compliance with streamlined workflows to ensure data integrity. Molecular Devices Spectramax Plate Reader. A. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. We would like to show you a description here but the site won’t allow us. $199. Color intensities were measured using microplate reader (Versamax, Molecular Devices, Inc. 003 OD ±1. US HEADQUARTERS. Our specialization servicing microplate instrumentation and our focus on a narrow range of product lines allows us to provide the highest standards of service and ensure. . The sections were stained with hematoxylin and eosin (H&E) and. VersaMax,SpectraMax340PC384,190,Plus384MicroplateReadersUserGuide 11 0112-0126B Theguidelinesforcuvetteuseintheinstrumentarethesameasthosethatapplytoany high. Biosystems CytoFluor 4000 Multi Well Plate Reader $ 1,995. However, whether these cells exhibit the serotonergic neuronal phenotype observed in mature hippocampal neurons. P. Oil red O staining. We would like to show you a description here but the site won’t allow us. The quantity of nitrite in the samples was calculated using the concentration of sodium nitrite as a standard. The cortisol-driven molecular programming of HPI axis development has focused only on GR signalling in fishes 12,13,14,15,16,17. Direct cytotoxicity of HVJ-E and Laserphyrin®-HVJ-EThe MTT formazan crystals were dissolved by adding 50 μl DMSO to each well and the plates gently shaken until the MTT solution was dissolved. The absorbance at wavelength 450 nm was detected using a micro-plate reader (VersaMax, Molecular Devices, USA). The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. Reboot the computer. Absorbance was read at 412 nm every minute for 10 min using a VersaMax (Molecular Devices, San Jose, CA) spectrophotometer. VERSA MAX-LUNABLE, MOLECULAR DEVICES, MICROPLATE R. The nuclear extracts were subsequently determined for the content of NF-κB with the NF-κB (p65) transcription factor assay kit. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. Formerly known as MicroMax, Molecular Devices’ unique SpectraDrop™ Micro-Volume Microplate, offers the highest throughput solution for low volume measurement available onthe market today. MOLECULAR DEVICES VersaMax Reader: Model #: VersaMax: Serial #: N/A: Year Built: N/A: Location: California: Price: $3,800. 5×10 3 cells were seeded in 96-well plates, treated with indicated inhibitors for 48 or 72 hours, analyzed 16 hours after BrdU addition, and absorbance measured at 450nm using a spectrophotometer plate reader (VersaMax, Molecular. Invasion assayCells were seeded into the top chamber of a 96-well matrigel-coated plate with 8-m-pore polyethylene terephthalate membrane inserts (Corning). The percentage of cytotoxicity was calculated using the following formula: cytotoxicity (%) = [1 − (At/As) × 100], where At and As refer to the absorbance of a tested. Model : VersaMax . Home - University of Victoriaimported directly into Excel (Microsoft, Redmond, WA) from the ELISA microplate reader (VersaMax; Molecular Devices, Sunnyvale, CA, USA). Select Update Driver. Finally, a 5% glucose solution was added to the suspension of CPN and FCPN as a freeze-dried protective agent. 4. DMEM medium supplemented with the same volume of kit reagent on an empty well was used as a blank. absorbance readers. 99 + $91. This. Click SoftMax Pro Software User Guide. Phosphodiesterase isozymes: molecular targets for novel antiasthma agents. 1700 +1 800. 47 shipping. Sterile AB medium and a mixture of Me 2 SO, methanol, and water (ratio v/v 1:1:8) served as negative controls. Molecular Devices memberdayakan para ilmuwan untuk memajukan diagnosis dini dan terapi yang lebih aman untuk pasien. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. Indocyanine Green Depuration Assay. +44-118-944-8000. Cell proliferation. The emodin thermoreversible PG was. Molecular Devices Corporation SpectraTest ABS1 Validation Plate Warranty Molecular Devices Corporation warrants this product against defects in material or workmanship as follows: 1. Access this by going to. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. With its advanced features and user-friendly interface, the VersaMax is the perfect choice for a wide range of research. Absorbance was read on a spectrophotometer (VersaMax, Molecular Devices) with SoftMax Pro GxP v5 software. Spectrofluorometer (e. Cet appareil ISM est confomre à la norme NMB-001 du Canada. Taking into account the price differences between each seller and each country. Tunable, filterless flexibility The. 72 MB. 00 Read more Molecular Devices Tunable Microplate Reader VersaMaxMicroplate reader with 450 nm filter, such as VersaMax (Molecular Devices, Sunnyvale, CA). Antioxidant enzyme activityProtein concentration was determined from diluted crude venom and nanoparticle samples (1 mg/mL) in deionized water by BCA™ Protein Assay using a UV/V spectrophotometer (VersaMax, Molecular Devices, CA, USA) at a wavelength of 562 nm. and California) Tunable Microplate Reader 100-240V ~ 4A 50-60 HZ T4. Microplate Reader Shelf. Molecular aspects of color variation in luciferase emission have been the subject of numerous studies: various mechanisms have been proposed [6] and multicolor reporter proteins have been created and applied in cell-based. +81-3-5282-5261 SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. The absorbance was measured using a microplate reader (VERSAmax; Molecular Devices, San Jose, CA, USA) at an excitation wavelength of 530–560 nm. StakMax. The Molecular Devices SpectraMax XPS has an optical design that is the only multi-channel system that truly mimics a dual-beam spectrophotometer. GABase was a mixture of γ-aminobutyrate glutamate amino transferase. The number of cells that migrated to the bottom was determined by measuring the optical density at 590 nm, using a microplate reader (VersaMax; Molecular Devices). StakMax. Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part #0112-0140 Rev. ISM Equipment Classification (Group 1, Class A) This equipment is designated as. Results of host range test of Mae-Yong924-1 against. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. S. 99 shipping. Electrolyte leakage analysis was conducted using 8-day-old rice seedlings before and after cold stress treatments in different time points (0, 6, and 11 days) at 4°C. 0A 2 Lines Fused, unplug before ser. 단일 튜브 디스펜싱에서 전체 96 및 384 well 플레이트세척까지 간소화된 Microplate 세척입니다. Youmustensurethatthemeniscusiscomfortablyabove thelightbeaminstandardcuvettesandthatthesamplechamberinamicrocuvetteis Microplate Reader Capability > UV - Vis Absorbance. The Molecular Devices VersaMax ELISA Microplate Reader enables precise and accurate detection at. from Molecular Devices Corporation. Molecular Devices Corporation Instrument Warranty Molecular Devices Corporation warrants this product against defects in material or workmanship as follows: 1) All parts of the VERSAmax Tunable Microplate Reader are warranted for a period of one (1) year from the original date of delivery. NORTH AMERICA +1 800-635-5577 Mon to Fri 7am - 5pm Pacific Time. Versamax Microplate Reader dibangun di sekitar monokromator kisi. Myeloperoxidase AssayThe SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. Molecular Devices VersaMax Microplate Reader. Biosystems CytoFluor 4000 Multi Well Plate Reader $ 1,995. The introduction of the Molecular Devices’ SPECTRAmax PLUS microplate spectrophotometer marks the first time that photometric measurements made in a microplate format can be automatically normalized such that the resultant values are identical to those obtained with the corresponding solutions in a standard 1 cm pathlength cuvette. All experiments were repeated three times. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes. Manufacturer: Molecular Devices; Includes PC Workstation w/ Softmax Pro Software Wavelength Range (nm): 340–850 Wavelength Accuracy: < ±0. Microwell plates, black (96-well) Rocking table with adjustable lifting frequency. The SpectraMax Plus 384 Microplate Spectrophotometer is a versatile and reliable instrument that can measure absorbance in the UV and visible range. Optical Densitiy (OD) values were processed with a data reduction software (SoftMax Pro, Molecular Devices) using a 4-parameter logistic fitting algorithm to the standard curve, allowing the determination of antibody. At All-usermanuals. ,, [28]. 0A Sunnyvale, CA Made in USA VersaMax price. The absorbance was read at 570 nm using a spectrophotometer (VersaMax, Molecular Devices, San Jose, CA, USA). Access all the resources, tools and information you need to stay productive. the plate reader (model VERSAmax, Molecular Devices, USA) at 515 nm (A515). The assay procedure was in accordance with the manufacturer's instructions, and the results were analyzed with a microplate reader (VersaMax; Molecular Devices Ltd. The SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance and can be equipped to read volumes as low as 2uL in one multimode reader package. 4. Resveratrol (1 µ M) was expected to produce a sufficient effect on ER-stress and ROS production and was applied for subsequent analysis; a dose-dependent effect was also investigated by using 1 and. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. VersaMax ELISA Microplate Reader from Molecular Devices, LLC Description Enables precise and accurate detection at wavelengths in the visible spectrum without the use of. An aliquot of the extracts dissolved in DMSO with 80 μL of phosphate buffer (pH 6. to 11. Cellular imaging was performed on a Confocal microscope (Olympus IX 81 + FV1000, Shanghai, China) using an excitation wavelength of 380 nm. High-Throughput Screening. 1 N NaOH (50 μl) followed by absorbance measurement at 405 nm with a plate reader (VersaMax, Molecular Devices, Sunnyvale, CA). The Molecular Devices VersaMax Absorbance Microplate Reader enables both precise and accurate detection at wavelengths in the visible spectrum without the use of filters, providing consequence-free assay flexibility. Unit price / per . To evaluate the reliability of the assay, SkinEthic TM RHE (1% Triton X-100) was used. The calibration curve was fitted to a sigmoid by the four-parameter method in the SoftMax Pro software (Molecular Devices), and allowed the calculation of the concentration of native Antigen 18A. Molecular Devices VersaMax Microplate Reader Molecular Devices VersaMax Microplate Reader Specifications. 003 OD ±1. g. Preparation of cytoplasmic and nuclear protein. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. 0 OD Kinetic Read Time: 9 Second Minimum Interval Temperature Uniformity ±0. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. Data were normalized to those of the PBS exposure control group. To update the driver. SpectraTest ABS1 Absorbance Validation Plate. Technical Specifications. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. 5 × 10 6 cells per well inoculated into 6-well plates in culture medium with CSF1 (10 ng/mL) for 7. SpectraMax Plus384 SpectraMax 190 SpectraMax 340PC384 VersaMax Microplate Spectrophotometer Operator s Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. reader (VersaMax, Molecular devices, San Jose, CA, USA). This user guide provides detailed instructions on how to operate, maintain, and troubleshoot the device, as well as examples of applications and. This technical note is designed to provide information . 3860 N First Street San Jose,CA 95134 USA +1 408. Monitor reader performance on demand to ensure data quality is not compromised between PM/OQ. 0 software (GraphPad). Search for used versamax. To purchase a newer software version, request a quote. We would like to show you a description here but the site won’t allow us. After treatment with GA3The absorbance was measured with a microplate reader (VERSAmax, Molecular devices, San Jose, CA, USA) at 570 nm according to the manufacturer’s instructions. 5°C @ 37°C Well-to. The mouse hippocampal neuronal cell line HT22 is frequently used as an in vitro model to investigate the role of hippocampal cholinergic neurons in cognitive functions. The signal was read on an ELISA plate reader (SpectraMax VersaMax, Molecular Devices, Sunnyvale, CA, USA). 68 $. ® Standalone instrument with touchscreen and built-in sample ports for small volumes and cuvettes. Cells were lysed in NETN buffer (100 mM NaCl, 20 mM Tris pH 8. S. VersaMax Absorbance Microplate Reader memungkinkan pemilihan hingga dua panjang gelombang sekaligus untuk deteksi absorbansi dalam. Accession codes. It features a dual-monochromator system, a large dynamic range, and a high-throughput capability. 99 + $59. Absor-bance of the solution was measured using a micro plate Reader (VersaMax, Molecular Devices) at 570 nm. 90 shipping. Lipid accumulation was assessed by ORO staining. The blue formazan concentration formed in viable cells was measured at 570 nm using spectrophotometer (Versamax, Molecular Devices, São Paulo, Brazil). ®ABS2, FL1, and LM1 Validation Plates sent to Molecular Devices for recertification at our ISO 17025 accredited lab are disassembled, cleaned, calibrated, an then returned with a new certificate of calibration. SpectraMax Plus384, 190, 340PC384, and VersaMax Installation Guide Author: Molecular Devices Subject: Installation Guide Keywords: SpectraMax Versa and others Detection Platform Created Date: 5/17/2023 2:14:27 PM At 5 seconds to read a 96-well endpoint assay or a 5 second minimum interval between kinetic reads, the VMax Microplate Reader has both speed and performance. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. +81-6-6399-8211 fax +81-6-6399-8212 Nihon Molecular Devices Tokyo Tel. Molecular Devices Corporation reserves the right to change its products and services at any time to incorporate technological developments. All animal experiments were performed in compliance with the relevant laws and. 4 Microplate Reader Software w WARRANTY. Versamax Microplate Reader dibangun di sekitar monokromator kisi. ChE activity was normalized by protein concentration as determined by a Coomassie. SpectraMax® Microplate Reader User Manual Download Page. Absorbance was measured with a microplate reader (VERSAmax Molecular Devices Corporation, Sunnyvale, CA, USA) at 570 nm to assess cell viability. In this study, we have prepared thermoreversible PG containing emodin with high emodin solubility and the gelation temperature suited to physiological use. 0A Sunnyvale, CA Made in USAVersaMax price. SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers. Find regional support. 4. The SpectraTest® ABS1 Absorbance. The. EC migration was studied by wound healing assay. , Sunnyvale, USA). 0. 00 Add to cart Molecular Devices Microplate Reader Spectramax 384 340PC $ 6,295. $199. S. Concentration was determined by BCA Protein Assay Kit (ref. Then the absorbance at 570 nm was measured using a microplate reader (VersaMax, Molecular Devices, San Jose, CA, USA). Microplate readers from Molecular Devices are designed to provide consistent performance over a long period of time. It provides both rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. , Sunnyvale, CA, USA). Microplate readers from Molecular Devices are designed to provide consistent performance over a long period of time. Built around a grating monochromator, the VersaMax™ Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340–850nm). VersaMax,SpectraMax340PC384,190,Plus384MicroplateReadersUserGuide 11 0112-0126B Theguidelinesforcuvetteuseintheinstrumentarethesameasthosethatapplytoany high-qualityspectrophotometer. HUVECs were seeded into 96-well plates at a density of 30,000 cells/well and allowed to attach for 12 h. VERSAMAX. Molecular Devices VersaMax Tunable Temperature range between 4°C above ambient to 45°C Digital controller and display Sold as-is The Molecular Devices VersaMax. and California) Tunable Microplate Reader 100-240V ~ 4A 50-60 HZ T4. 2. The system provides automation for up to 50 For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. Molecular Devices, LLC. The absorbance was assumed to be 100% for the control group. HT22 cells are derived from hippocampal neuronal HT4 cells. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility offered by monochromator-based systems. TECHNICAL NOTE. We would like to show you a description here but the site won’t allow us. To test if sodium arsenite and dimethylarsenic acid could stimulate apoptosis in 3 cells, oc cell cycle redistribution was studied using flow cytometry with propidium iodide staining. Afterward, HUVECs were incubated with EPC-EVs, TFEB-EVs, or PBS for 24 h or 48 h. Regular price $ 0. Unit price / per . Statistical analysis Graphs and statistics were prepared in GraphPad Prism, version 7. Although this manual has been prepared with every precaution to ensure accuracy, Molecular Devices SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. S. Find Fanuc, Molecular Devices, Eagle, and GE for sale on Machinio. Cell viability was analyzed using a cell counting kit assay (Dojindo). ® The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. The well plates were then washed with 1% acetic acid and dried. All analyses were performed three times, and the mean values were used for further calculations. Select Start>Control panel>Device Manager. Sale Sold out. Molecular Devices Corporation. While the situation is vastly improving with numerous vaccine rollouts and over 6. Cell viability was expressed as percent survival of untreated cells. MOLECULAR DEVICES VMAX KINETIC MICROPLATE READER. In brief, mature 3T3-L1 cells were washed with DPBS, fixed with 10% formalin for 1 h at room temperature, washed once with 60%. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. For pinocytosis, cells in wells were washed in PBS and 5 mg/ml of HPTS dye (in PBS) added and incubated with gentle rocking at 30 °C for 120 min. In this study, we have prepared thermoreversible PG containing emodin with high emodin solubility and the gelation temperature suited to physiological use. 3, Molecular Devices). Optical Densitiy (OD) values were processed with a data reduction software (SoftMax Pro, Molecular Devices) using a 4-parameter logistic fitting algorithm to the standard curve, allowing the determination of antibody. A standard curve, provided by the manufacturer, was generated and the sample concentrations determined by 4-parameter logistic curve. We would like to show you a description here but the site won’t allow us. 3860 N First Street San Jose,CA 95134 USA +1 408. 00 USD. Find regional support. Select Update Driver. By measuring optical pathlength, it eliminates the last major distinction between microplate readers and spectrophotometers. for cell lysis via visual inspection and optical microscopy (VersaMax, Molecular Devices, Sunnyvale, CA, USA) observation and checked by measuring the absorbance at OD680. 6/10 #0120-1330d. MOLECULAR DEVICES VersaMax is a customizable lab equipment capable of performing multiple types of research-grade tests and experiments at once, with enhanced safety protocols and adjustable column and sample-loading system for efficient sample preparation and increased throughput. New and used Molecular Devices VersaMax's for sale on LabX. 0 out of 5 $ 2,999. Using a Spectradrop Micro-Volume Microplate (VersaMax, Molecular Devices, CA, USA), RNA was quantified, and 1 μg of total RNA was treated with DNase I (Thermo Scientific, Waltham, MA, USA) before. FRAP solutions were prepared as described previously (Benzie and Strain, 1996, Benzie and Strain, 1999). , Spectramax Gemini; Molecular Devices) Tissue culture plates (24- and 96-well) Vacuum suction pumpRelated products. 00. Study conductThe amounts of chlorophyll a and chlorophyll b were measured at 664. The cells were treated with 15, 25, 30, and 45 nm-particles in order to compare the cytotoxicities of different sized nanoparticles on the treated cells. Select Start>Control panel>Device Manager. 0 out of 5 $ 2,999. Cell viability was represented by percentage values compared to a control and then used to calculate the number of viable cells. Molecular devices The VersaMax Absorbance Microplate Reader costs between $5,500 and $6,600. Preconfigured method protocols specifically written for the Pyrochrome Assay and other ACC assays are available for SoftMax Pro Software and take. and California) Tunable Microplate Reader 100-240V ~ 4A 50-60 HZ T4. The absorbance of the mixture was measured with a microplate reader (VERSAmax™, Molecular device, Sunnyvale, USA) at wavelength of 498 nm until absorbance was saturated. For the MTS assay, the CellTiter 96® AQ ueous One Solution Cell Proliferation Assay kit was used following the manufacturer's instruction. That's why our team is at your disposal the majority of time. +86-21-6887-8820 fax +86-21-6887-8890 Germany Molecular Devices GmbH Tel. S. Molecular Devices FMax Thermo Fluoroskan Ascent Fluorescence Microplate Reader W WARRANTY $3,450. ® US HEADQUARTERS. The absorbance was measured at 450 nm using a microplate reader (VersaMax, Molecular Devices). We would like to show you a description here but the site won’t allow us. This document is provided to customers who have purchased Molecular Devices, Inc. +06-6399-8211 Fax +06-6399-8212 ©2002 Molecular Devices Corporation. The VersaMaxTM Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. . Cell viability was calculated using the following formula, where OD t is the absorbance of the treated cells and OD c is the absorbance of control cells: Cell viability = O D t / O D c. Plates were read using a microplate reader (VersaMax, Molecular Devices) at 595 nm. The absorbance was detected at 570 nm with a Microplate Reader (VersaMax, Molecular Devices, Sunnyvale, CA). Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. The wells were visualized using o-phenylenediamine (OPD), and the absorbance was read with a multiwall spectrophotometer (VERSAmax, Molecular Devices, Sunnyvale, CA, USA) at 490 nm. In the Apps and Features window, locate and uninstall SoftMax Pro. Study conductThe amounts of chlorophyll a and chlorophyll b were measured at 664. The collaborative space brings customers and researchers into the lab to test automated workflows for organoid culturing and screening, with guidance from in-house. VERSAmaxTM Tunable Microplate Reader Operator s Manual for Instruments with Serial Numbers Beginning. . Molecular Devices is one of the leading provider of high-performance bioanalytical measurement solutions for life science research, pharmaceutical and biotherapeutic development. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. Cell proliferation assay MDA-MB-231 cells were seeded at a density. SpectraMax ABS and ABS Plus Absorbance ELISA Microplate Readers. 00. For more advanced automation needs, Molecular Devices interacts with all of the major lab automation providers, and is one of their leading choices. 5) containing 0. Spectranet customer portalSpectraMax and VersaMax . Results are presented as the geometric mean and are derived from at least three experiments. SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers. Negative (phosphate buffered saline) (Gibco Waltham, MA, USA) and positive controls. ImmunohistochemistryAfter 1 h incubation at 37 °C, the color intensity was measured at 562 nm by a microplate reader (model VERSAmax; Molecular Devices, San Jose, CA, USA).